Three-phase four-wire current-limiting overvoltage and underVoltage Protector protection parameter settings 1. Press the SET key for 2 seconds to enter the password page. Press the DATA key and SHIFT key to enter the password, then press SET once to confirm the password. 2. Enter parameter setting. Press the DATA key and SHIFT key to set parameters. 3. Press the SET key to enter the next parameter setting. 4. After all parameters are set, press the RESET key for 2 seconds to save and exit, returning to real-time display.
2025-04-11Author: 江光电气
Control and protection switch wiring diagram, control and protection switch manual, control and protection switch setup and commissioning, how to set parameters for a control and protection switch
2025-01-03Author: 江光电气
Most end users encounter various problems when using multifunction power meters. Those with work experience can easily find solutions, but some beginners may not be able to, so we asked our technical after-sales team to compile some common usage issues. 1. Does the meter need a current transformer when measuring current? The meter's current measurement range is AC 0-5A, and the voltage measurement range is AC 0-450V. If the current to be measured exceeds the meter's measurement value, a current transformer must be installed, by changing the meter's...
2025-01-03Author: 江光电气
Summary: Common faults of self-recovery over/under Voltage Protectors. Keywords: self-recovery over/under Voltage Protector, three-phase four-wire self-recovery over/under Voltage Protector, self-recovery over/under Voltage Protector 4P, auto-recovery over/under Voltage Protector, overVoltage Protector. The self-recovery over/under Voltage Protector is a voltage protection type protector, currently used in various power distribution circuits for voltage protection. We have now compiled some of the problems customers have encountered during use and selected some common questions to help users.
2025-01-03Author: 江光电气
As the use of JGKB control and protection switches continues to increase, we have compiled the issues reported by customers, hoping to help solve problems encountered in daily use. 1. Suspected causes of abnormal heating in control and protection switches: A. Loose terminal screws and conductor wiring screws; B. Increased contact resistance at the terminals causes heating, internal locking becomes loose, and broken braided wires cause increased current density; C. The pH level of the surrounding air severely exceeds the standard, causing increased contact resistance and heating at the terminals. Solution: Tighten the terminal screws.
2015-02-28Author: 江光电气
This situation is completely normal. The over-voltage and under-Voltage Protector only powers on after it detects that the voltage is normal and stable. For example, the JGGQ-100S/3P+N over-voltage and under-Voltage Protector launched by Wenzhou Jiangguang Electrical Technology Co., Ltd. powers on when it detects that the voltage is normal and stable, and trips in cases of over-voltage at 275V and under-voltage at 170V, providing effective protection for circuits and equipment